40
TABLE 5.  SUGGESTED DEFINITION OF EXCEPTIONALLY
HIGH-RISK BUILDINGS
Seismicity
Occupancy
Model Building Type
Age
Bureau Essential
High
1991
NEHRP
Zones 5,6,7
-Schools
-Clinics
- Fire           
Stations
-Emergency 
Ops Center
-Dormitory
-Office w/
  Day Care
-Places of
  Assembly
-Detention
  Center
Precast/Tilt-Up Concrete Walls
>7yr
Special Historic
Communication
  Center
Expensive Equip.
Hazmat Storage
Precast Concrete Frames/Concrete
Shear Walls
Reinforced Masonry Bearing Walls
w/ Wood/Metal Deck Diaphragms
Reinforced Masonry Bearing Walls
w/ Precast Concrete Diaphragms
Unreinforced Masonry Bearing Wall
Buildings
(Model Building Types 11 thru 15 as identified in FEMA 178.)